Safe High Voltage (SHV) feedthroughs are like the MHV series, with the primary difference being the pin and contact configuration. SHV cable connectors have a recessed female contact which helps prevent shock hazards when the connector is disengaged. This recessed contact design is an improvement over the MHV design, and becomes increasingly important in higher power applications. The SHV-5 and SHV-10 series are rated for up to 5 Amps and 5000 or 10,000 Volts DC respectively. Both are offered in single and double-ended versions.
Operating Conditions
The electrical and thermal ratings specified are safe operating limits determined by various factors including material properties, mechanical design, and the intended operating environment. All electrical ratings are based on operation with one side in dry atmosphere and the other side in vacuum of 1 x 10-4 Torr maximum pressure. Temperature ratings for various mounting options may reduce the operating range of an assembly. All assemblies have a maximum thermal gradient of 25oC per minute and may be damaged if this limit is exceeded.
|
SHV-5 Grounded
| Single/Double Ended: |
Single/Double |
| Electrical Rating: |
Voltage: 5000 Volts DC Current: 5 Amps |
| Thermal Rating: |
Feedthrough: -200 to 450oC Air-side Connector: -65 to 165oC
|
Conductor:
|
Nickel
|
Impedance:
|
Non-constant
|
SHV-5 Floating
| Single/Double Ended: |
Single |
| Electrical Rating: |
Voltage: 2500 Volts DC Current: 5 Amps |
| Thermal Rating: |
Feedthrough: -200 to 450oC Air-side Connector: -65 to 165oC
|
Conductor:
|
Nickel
|
Impedance:
|
Non-constant
|
|